List of Variables of Dimensioning

To perform dimensioning analysis it is first necessary to choose the option "Carry out dimensioning" in the frame "Dimensioning parameters". Visualization of values for dimensioning can be set in the toolbar "Results". Notation of variables (particularly indexes of variables) changes according to the standards used for dimensioning of concrete and steel structures set in the "Material and standards" tab.

List of quantities displayed by the program for dimensioning

Variable

Unit

Description

Moment Mdim1, min

[kNm/m]

Minimal dimensioning moment in direction of reinforcement 1

Moment Mdim1, max

[kNm/m]

Maximal dimensioning moment in direction of reinforcement 1

Moment Mdim2, min

[kNm/m]

Minimal dimensioning moment in direction of reinforcement 2

Moment Mdim2, max

[kNm/m]

Maximal dimensioning moment in direction of reinforcement 2

Reinforcement area Au1

[mm2/m]

Area of upper reinforcement in direction 1

Reinforcement area Ab1

[mm2/m]

Area of bottom reinforcement in direction 1

Reinforcement area Au2

[mm2/m]

Area of upper reinforcement in direction 2

Reinforcement area Ab2

[mm2/m]

Area of bottom reinforcement in direction 2

Ratio of reinforcement μh1

[%]

Reinforcement ratio of upper reinforcement in direction 1

Ratio of reinforcement μd1

[%]

Reinforcement ratio of bottom reinforcement in direction 1

Ratio of reinforcement μh2

[%]

Reinforcement ratio of upper reinforcement in direction 2

Ratio of reinforcement μd2

[%]

Reinforcement ratio of bottom reinforcement in direction 2

Shear force VEd

[kN/m]

Dimensioning shear force

Reinforcement area Ab,nut

[mm2/m2]

Requested area of shear reinforcement

Shear force VRd, c

[kN/m]

Shear strength of cross-section without shear reinforcement

Shear force VRd, max

[kN/m]

Maximal allowable shear force