GEO5

Hướng dẫn trực tuyến

Tree
Settings
Chương trình:
Ngôn ngữ:

Verification According to Limit States

The verification according to limit states is selected in the "Pile CPT" tab, including the setting of the pile bearing capacity reduction coefficient. When using the NEN 6743 standard the program automatically performs the verification analysis as specified by this standard and therefore the frame "Settings" is not accessible. Pile verification for the first limit state assumes the formula:

where:

Fs,d

-

design pile load

γt

-

reduction coefficient of bearing capacity

Fr,d

-

design pile bearing capacity

Hãy tự trải nghiệm GEO5. Miễn phí.